Japan’s Onagawa nuclear plant builds a 95-foot seawall after the 2011 tsunami, before restarting Unit 2 in 2024
The 2011 tsunami in Japan dealt a devastating blow to the nation’s infrastructure.
Among those that took the biggest hits were the country’s nuclear power plants.
Some were completely wrecked and had to be shut down.
Lindi is a copywriter and marketing professional with over 10 years of experience across finance, fintech, luxury lifestyle, and renewable energy.
Yet, others managed to survive the catastrophe.
One such is the Onagawa Nuclear Power Station in Miyagi Prefecture.
What new coastal barriers and backup systems did engineers build at Onagawa to enable them to restart Unit 2 in 2024?
When the magnitude-9 earthquake and tsunami hit Japan’s Onagawa Nuclear Power Station
Whether by luck or providence, Onagawa Nuclear Power Station happened to be located at the epicenter of the earthquake.
So when the magnitude-9 earthquake struck the facility, within three minutes, the nuclear reactors completely powered down.
The reactors reached cold shutdown with no fuel damage or release beyond limits, and the cooling systems held up.
However, the tsunami wave that followed 30-min later did manage to breach the facility.
Tsunami water entered from the station’s intake channel into the seawater pump room through a water-level gauge box.
It submerged the reactor pump area and flowed through an underground trench into the heat exchanger rooms.
When that happened, it stopped the emergency diesel generators and disabled two cooling systems from working.
So while the nuclear reactors survived the earthquake, several components of the nuclear plant were damaged by the tsunami.
Tohoku Electric Power implements multi-layered tsunami defense and station-wide safety upgrades
To no one’s surprise, Japan completely overhauled its nuclear safety rules after the tsunami disaster.
Tohoku Electric Power (TEP), the owner and operator, was required to repair all damaged components.
In addition, the operator had to implement extensive facility-wide upgrades to meet the stringent new regulatory standards.
TEP raised the main seawall to approximately 29 meters above sea level (about 95 feet) along an 800-meter span.
They also reinforced the wall with debris barriers to withstand hits from vessels and vehicles washed by the ocean.
In addition, TEP placed gas turbine generators as backup for diesel generators.
They built a 10,000-ton freshwater tank with the capacity for seven days of reactor cooling. They placed it on 60-meter-high ground,
Finally, they buried diesel fuel tanks underground and reinforced reactor building roofs and piping.
Onagawa Unit 2’s 2024 restart and grid connection milestones
Thirteen years after the disaster, Onagawa’s post-tsunami construction finally culminated in May 2024.
Tohoku Electric Power finished all facility repairs and completed all the safety upgrades to comply with the new rules.
The 95-foot coastal barrier, flood walls, and elevated power systems cleared final regulatory checks for restart.
In late 2024, the 825-MW boiling water reactor was connected to the grid and resumed commercial operation on December 26, 2024.
Unit 2 became the first reactor in Japan to restart, following regulatory approval and local consent.
TEP also added new systems to trap radioactive steam, prevent hydrogen explosions, and stop fires.
And to make sure they stayed prepared at all times, they added an emergency response building to the facility.
The building serves as the local response headquarters in the event of a nuclear disaster.
95-foot seawall with elevated backup power reshapes Onagawa Unit 2’s defense against future tsunamis
The wreckage that the 2011 Japan tsunami brought has since been unprecedented.
The country’s nuclear power plants suffered catastrophic losses, the worst of which was Fukushima Daiichi.
After three notable explosions, Fukushima was completely wrecked and had to be shut down.
While there were breaches at Onagawa Nuclear Power Station, all was not lost. Even though repairs and upgrades took 13 years, the plant was able to restart again.
A 95-foot seawall with elevated backup power and cooling reshaped Onagawa Unit 2’s defense against any future tsunamis to come.
Lindi is a copywriter and marketing professional with over 10 years of experience across finance, fintech, luxury lifestyle, and renewable energy. She writes with a keen interest in the business and innovation shaping the energy transition.