GE Vernova unveils SF₆-free compact switchgear designed to cut substation footprint by at least 50%

At the Power Transmission and Distribution Technology conference in Cologne on November 17, 2026, GE Vernova unveiled the HYpact-145g — a 145 kV, 40 kA compact switchgear built without sulfur hexafluoride. Instead of SF₆, the unit runs on g3, a mixture of carbon dioxide, oxygen, and a small amount of fluoronitrile.
The announcement targets network operators who need to modernize high-voltage substations where space to expand is limited — and who are under growing pressure to move away from SF₆.
GE Vernova introduces the HYpact-145g at Cologne conference
GE Vernova made the HYpact-145g official on November 17, 2026, during the opening day of the Power Transmission and Distribution Technology conference in Cologne, Germany. The event runs through November 19, and the company is displaying a full-scale 145 kV SF₆-free model at Stand 8026 — actual hardware, not a brochure rendering.
The g3 gas mixture combines carbon dioxide, oxygen, and a small amount of fluoronitrile (C4F7N), replacing SF₆ as the insulating and arc-quenching medium.
Rated at 145 kV and 40 kA, the product sits squarely in the high-voltage transmission category. It’s designed for substations where major high-voltage lines and large electrical equipment connect — the backbone infrastructure that keeps the broader grid running. The g3 gas mixture combines carbon dioxide, oxygen, and a small amount of fluoronitrile (C4F7N), replacing SF₆ as the insulating and arc-quenching medium. The HYpact-145g is available to order now, with manufacture planned at GE Vernova’s facility in Kassel, Germany.
Why operators are seeking SF₆-free, space-saving switchgear
SF₆ has been the industry standard insulating gas for high-voltage switchgear for decades. It performs exceptionally well electrically. What it does to the atmosphere is the problem — more on that shortly — and regulatory pressure combined with sustainability commitments are pushing grid operators to find alternatives.
Space is the other constraint. Many substations were built in locations now hemmed in by urban development, with no room to expand the fence line, yet these same sites need to handle more load as electrification grows. Shrinking the footprint while dropping SF₆ is exactly the problem the HYpact-145g is designed to solve.
GE Vernova didn’t start from scratch. The company has been working with g3 for more than a decade and previously developed a 145 kV SF₆-free dead tank circuit breaker — experience that engineering teams drew on directly when designing this compact switchgear.
How the HYpact-145g reduces space and environmental impact
The HYpact-145g uses a hybrid design that combines gas-insulated and air-insulated components in a single unit. That’s what drives the space reduction. According to GE Vernova, the switchgear takes up at least 50% less space than a conventional air-insulated substation while still meeting transmission-network performance and reliability standards — a meaningful difference when cutting the physical footprint in half can make an upgrade feasible where a conventional replacement simply wouldn’t fit.
On the environmental side, the g3 mixture replaces SF₆ without requiring operators to sacrifice technical performance. Interrupting and insulating standards remain at the level expected for transmission-class equipment.
Digital operation is also supported. Operators can specify optional low-power instrument transformers (LPITs) — sometimes called digital voltage and current transformers — for voltage and current measurement in monitoring and control applications. That makes the HYpact-145g compatible with the digital substation architectures many utilities are now building toward.
Context: SF₆ phase-out and the GRiDEA™ portfolio
The urgency around SF₆ replacement comes down to one number: its global warming potential is roughly 23,500 times that of CO₂ over a 100-year period, making it one of the most potent greenhouse gases in industrial use. For regulators and utilities with emissions reduction targets, phasing it out wherever technically viable alternatives exist is a genuine priority — not a distant aspiration.
The HYpact-145g joins GE Vernova’s GRiDEA™ portfolio, which groups together the company’s high-voltage transmission technologies aimed at reducing SF₆ reliance. Safe, reliable, and efficient grid operation anchors the portfolio, with the added objective of helping customers cut their dependence on the gas.
Luc Doms, Strategy & Product Management Leader for GE Vernova’s Electrification segment, framed the launch in terms of operator choice: “Operators want to move away from SF₆ without giving up the performance, reliability, compactness and optimal carbon footprint their substations require. The HYpact-145g is another important addition to our range of SF₆-free technology, offering operators greater choice and flexibility as they upgrade their systems.”
What the HYpact-145g launch means in practice
The HYpact-145g is a 145 kV, 40 kA compact switchgear that replaces SF₆ with g3 gas, cuts substation footprint by at least 50% versus conventional air-insulated designs, and supports optional digital instrument transformers. It’s available to order now, with manufacturing planned at GE Vernova‘s Kassel facility.
The launch adds another option to the GRiDEA™ portfolio at a moment when grid operators face simultaneous pressure to modernize aging infrastructure, reduce SF₆ emissions, and accommodate growing electricity demand — often within the physical boundaries of substations that simply can’t be expanded.
Kelly is an experienced writer with 15 years of experience exploring the big stories that shape our world, from tech breakthroughs and space exploration to climate, energy, and the fascinating quirks of science. She has a talent for turning complex ideas into sharp, memorable insights that stay with readers long after they’ve finished reading.